HPLC Column, RP C4 Butyl, 5um, 2.1mm ID x 100mm Length, 100A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C4™ is a reversed-phase HPLC stationary phase designed for the separation of hydrophobic and neutral compounds where less retention is desired than with traditional C8 or C18 phases. Manufactured using a four-carbon butyl ligand bonded to ultra-high purity silica and fully double end capped, this stationary phase provides reproducible chromatographic performance and is widely used as an alternative in USP methods requiring L26 chemistry. Its reduced hydrophobicity compared to longer-chain bonded phases makes it particularly useful for rapid analyses, method development, and LC-MS workflows.
68504-10P-2 is an HPLC column packed with 5 µm RP C4™ particles featuring a 100 Å pore size in a 2.1 mm ID x 100 mm format. This narrow-bore configuration combines enhanced chromatographic resolution with reduced solvent consumption and excellent compatibility with LC-MS instrumentation. The 100 mm length provides greater resolving power than shorter 50 mm columns while maintaining practical analysis times. The 5 µm particles provide low backpressure and robust operation. Typical operating flow rates are approximately 0.2–0.3 mL/min. As with all 2.1 mm ID columns, the HPLC system must be capable of precise and reproducible low-flow operation.
This column is commonly used for hydrophobic and neutral compounds in reversed-phase HPLC when reduced retention is desirable. Compared to C8 phases, RP C4™ typically provides lower retention, making it useful for compounds that may be excessively retained on more hydrophobic stationary phases. The 2.1 mm ID format is particularly popular for LC-MS workflows due to reduced solvent consumption, improved detector sensitivity, and efficient analyte transfer to the mass spectrometer.
Key Benefits
RP C4™ stationary phase
USP L26 equivalent chemistry
Butyl bonded phase
Fully double end capped
Ultra-high purity silica support
Less retention than C8 phases
Suitable for rapid analyses
Lower backpressure than smaller particle columns
5 µm particle size
Excellent for LC-MS applications
Typical Applications
USP L26 methods
LC-MS methods
Method development
Method scouting
Hydrophobic compound analysis
Neutral compound analysis
Reversed-phase HPLC
Pharmaceutical analysis
Quality control testing
High-throughput analysis
Specifications
Product Type: HPLC Column
Stationary Phase: RP C4™
USP Classification: L26
Chromatography Mode: Reversed Phase
Bonded Phase: Butyl (C4)
Endcapping: Fully Double End Capped
Particle Size: 5 µm
Pore Size: 100 Å
Column Dimensions: 2.1 mm ID x 100 mm
Length: 100 mm
Typical Flow Rate: 0.2–0.3 mL/min
Brand: Cogent
Important Notes
Designed for hydrophobic and neutral compounds
Provides less retention than C8 stationary phases
Suitable for rapid reversed-phase separations
The 2.1 mm ID format is ideal for reduced solvent consumption and LC-MS compatibility
Standard HPLC systems must be capable of reliable operation at approximately 0.2–0.3 mL/min
Detector flow cells should be optimized for low-volume, narrow-bore chromatography
The 100 mm length provides greater resolution than 50 mm columns while maintaining practical run times
5 µm particles allow lower backpressure operation and robust performance
Fully double end capped to minimize secondary interactions
Frequently used for method development and scouting studies